250A 25kV Txuas Ncaj

Koj tuaj yeem paub txhua yam khoom tshiab yuav raug luam tawm ntawm no, thiab ua tim khawv rau peb txoj kev loj hlob thiab kev tsim kho tshiab.

250A 25kV Txuas Ncaj

Hnub Tim: 03-30-2022

Nta:

Muab kev sib txuas uas raug tshuaj xyuas tag nrho thiab sib cais tau tag nrho thaum sib phim nrog lub bushing lossis ntsaws kom raug.
Ua qhov chaw sim capacitive los txiav txim siab qhov xwm txheej ntawm lub voj voog lossis nruab ib lub cim qhia qhov txhaum.
Tsis muaj qhov yuav tsum tau ua kom tiav theem tsawg kawg nkaus.
Kev teeb tsa tuaj yeem yog ntsug, kab rov tav, lossis txhua lub kaum sab xis nyob nruab nrab.

Daim Ntawv Thov:

1. Rau kev txuas ntawm polymeric cable rau transformers, switchgear, motors thiab lwm yam khoom siv nrog lub connector pre-molded separable.

2. Rau kev teeb tsa sab hauv tsev thiab sab nraum zoov.

3. Lub zog hluav taws xob txog li 24 kV.

4. Tam sim no txuas ntxiv mus 250 A (300 A overload rau 8 teev).

5. Cov ntsiab lus ntawm Cable:

- Polymeric cable (XLPE, EPR, thiab lwm yam)

-Cov tooj liab los yog txhuas conductors

- Cov ntxaij vab tshaus semiconducting lossis cov ntxaij vab tshaus hlau

-Qhov loj ntawm tus neeg xyuas pib 25 ~ 120 mm2

111

Cov Qauv:

Ua tau raws li qhov yuav tsum tau ua ntawm GB/T 12706.4-2002 thiab IEC 60502.4-2005.

111

Cov ntsiab lus ntawm cov khoom siv:

Tus txuas ncaj

Tooj liab los yog Aluminium conductor cable lug

Cov cuab yeej siv hlau

Daim ntawv tshem tawm

Cov roj nplua nyeem silicone

Daim ntawv qhia kev teeb tsa

Daim ntawv pov thawj zoo

Cov Ntaub Ntawv Txog Kev Txiav Txim:

Kev piav qhia Tus lej siv. Kev hla ntawm tus neeg xyuas pib (mm²) Kev Ncab Ntau Ntau Overinsulation (hli)
15kV 250A Load break Straight Connector AH ZTS-15/250-25 25 16.3-19.9
15kV 250A Load break Straight Connector AH ZTS-15/250-35 35 16.3-19.9
15kV 250A Load break Straight Connector AH ZTS-15/250-50 50 16.3-19.9
15kV 250A Load break Straight Connector AH ZTS-15/250-70 70 19.8-23.5
15kV 250A Load break Straight Connector AH ZTS-15/250-95 95 23.1-27.1
15kV 250A Load break Straight Connector AH ZTS-15/250-120 120 23.1-27 .1
25kV 250A Load break Straight Connector AH ZTS-25/250-35 35 23.1-27 .1
25kV 250A Load break Straight Connector AH ZTS-25/250-50 50 23.1-27.1
25kV 250A Load break Straight Connector AH ZTS-25/250-70 70 23.6-26.4
25kV 250A Load break Straight Connector AH ZTS-25/250-95 95 23.6-26.4
25kV 250A Load break Straight Connector AH ZTS-25/250-120 120 27.9-33.5

111

Cov Qauv Khoom:

1, Conducting Rod: tus pin hom crimp connector yuav yog tooj liab los yog bimatel.

2, SEMI-CONDUCTIVE INSERT: Molded EPDM conducting roj hmab shielded tswj kev ntxhov siab hluav taws xob.

3, Capacitive Test Point: Capacitive test point muab ib txoj hauv kev los xyuas qhov xwm txheej ntawm lub voj voog. Lub hau roj hmab EPDM molded conducting earths qhov chaw sim thaum tsis siv.

4, Kev Nyuaj Siab: Kev teeb tsa ntawm lub vijtsam sab nraud thiab rwb thaiv tsev muab kev nplij siab rau cable.

5, Cable Nkag: Qhov qhib loj muab kev cuam tshuam kom haum rau kev tswj hwm qhov ntsuas dej.

6, SEMI-CONDUCTIVE SHIELD: Molded EPDM conducting roj hmab mates nrog

lub vijtsam cable kom tswj tau qhov kev sib txuas ntawm lub vijtsam thiab xyuas kom meej tias qhov kev sib dhos yog nyob ntawm lub zog hauv av.

7, Qhov Muag Av: Moulded rau hauv lub vijtsam sab nraud rau kev sib txuas ntawm cov xov hlau av.

8, Kev rwb thaiv tsev: Cov roj hmab EPDM insulating uas tau tsim thiab sib xyaw ua ke hauv tsev kom ntseeg tau tias zoo.

9, Xauv Nplhaib Groove: Kev npaj rau lub nplhaib xauv peb theem xaiv tau.

111