25kV 250A Load break Lub Luj Tshib Connector
1. Nws yog ib qho insulated tag nrho, kaw tag nrho, kov tau thaum lub zog plug-in davhlau ya nyob twg taub hau.
2. Nws yog dav siv rau hauv cov transformers faib sab nraum zoov, American box-type transformers, ring main units, cable branch boxes, underground transformers thiab lwm yam khoom siv hluav taws xob rau kev sib txuas.
3. Nws siv cov khoom rwb thaiv tsev EPDM (triple roj hmab) zoo.
  • Cov Lus Qhia Txog Khoom

  • Cov Cim Npe Khoom

Anhuang tshwj xeeb hauv LoadbreakLub Luj Tshib Txuas, peb muab cov khoom siv Loadbreak zooLub Luj Tshib Txuas.

Nta:

l Muab kev sib txuas sib cais tag nrho thiab sib txuas tau tag nrho thaum sib txuas nrog lub bushing lossis ntsaws kom raug.

l Ua-hauv capacitive xeem taw tes los txiav txim siab lub voj voog xwm txheej lossis nruab ib qho qhia txog qhov txhaum.

l Tsis muaj qhov yuav tsum tau ua kom tiav theem tsawg kawg nkaus.

l Kev teeb tsa tuaj yeem ua ntsug, kab rov tav, lossis txhua lub kaum sab xis nyob nruab nrab.

Daim Ntawv Thov:

l Rau kev txuas ntawm polymeric cable rau transformers, switchgear, motors thiab lwm yam khoom siv nrog lub connector separable pre-molded.

l Rau kev teeb tsa sab hauv tsev thiab sab nraum zoov.

l Lub zog hluav taws xob txog li 24 kV.

l Tam sim no txuas ntxiv mus 250 A (300 A overload rau 8 teev).

l Cov ntsiab lus ntawm Cable:

-Polymeric cable (XLPE, EPR, thiab lwm yam)

- Cov tooj liab los yog txhuas conductors

-Semiconducting los yog cov ntxaij vab tshaus hlau

- Tus neeg xyuas pib loj 25-120 mm²

Cov Kev Ntsuas:

Kev Ntsuam Xyuas Txheej Txheem:

(Um) Qhov system siab tshaj plaws: 25kV

Lub zog hluav taws xob impulse: 125kV

AC tiv taus qhov hluav taws xob, 5 feeb: 54kV

Kev ua haujlwm tas mus li: 250A

Kev Thauj Khoom Ntau Dhau (8 teev. Max.) :300A

Luv luv Circuit Court withstand: 12.5kA / 1s

LUS CEEV: Tag nrho cov ntaub ntawv raws li cov qauv IEC, Tsis yog qhov txwv.imgggCov Qauv Khoom

1, Conducting Rod: Tin-plated tooj liab pin screws rau hauv tus neeg xyuas pib sib cuag nrog lub hex key muab.

2, SEMI-CONDUCTIVE INSERT: Molded EPDM conducting roj hmab screen tswj kev ntxhov siab hluav taws xob.

3, Kev rwb thaiv tsev: Cov roj hmab EPDM insulating uas tau tsim thiab sib xyaw ua ke hauv tsev kom ntseeg tau tias zoo.

4, Rub Qhov Muag: Encapsulated stainless hlau rub qhov muag nrog ib qho zoo rau txoj hauj lwm bail.

5, Capacitive Test Point: Capacitive test point muab txhais tau tias los xyuas qhov xwm txheej ntawm lub voj voog. Lub hau roj hmab EPDM uas ua los ntawm cov pwm muab lub foob dej tsis pub dej nkag.

6, Kev Nyuaj Siab: Qhov kev teeb tsa ntawm sab nraud shielded thiab lub cable adapter muab cable kev nyuaj siab relief.

7, Cable Adapter: Qhov qhib loj muab thiab interface haum kom muaj lub foob dej tsis nkag.

8, Qhov Muag Av: Moulded rau hauv lub vijtsam sab nraud rau kev sib txuas ntawm lub xov hlau av.

9, SEMI-CONDUCTIVE SHIELD: Molded EPDM conducting roj hmab mates nrog lub vijtsam cable kom tswj tau qhov screen txuas ntxiv thiab xyuas kom meej tias lub rooj sib txoos yog nyob rau hauv lub ntiaj teb muaj peev xwm.

10, Tus Neeg Txuas Cable: Inertia welded bimetallic compression connector lees txais tooj liab lossis txhuas conductors.

Kev piav qhia Tus lej siv. Tus neeg xyuas pib hlaseem (mm²) Ncab ntau dhaurwb thaiv tsev (hli)
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-25 24 16.3-19.9
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-35 35 16.3-19.9
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-50 50 16.3-19.9
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-70 70 19.8-23.5
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-95 95 23.1-27.1
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-120 120 23.1-27 .1
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-35 35 23.1-27 .1
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-50 50 23.1-27.1
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-70 70 23.6-26.4
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-95 95 23.6-26.4
24kV 250A Load break Lub Luj Tshib Connector AH ZT-10/250-120 120 27.9-33.5