1. TXHEEJ TXHEEM
Rotary Off-Ioad Tap changeryog hom qauv kho tshuab uas siv ntau tshaj plaws thiab siv dav tshaj plaws ntawm cov khoom siv hloov pauv resistive on-load. Lub luag haujlwm rau lub tap-changer yog tias peb tuaj yeem ua haujlwm lub tap-changer ntawm lub hau transformer, los ntawm kev tswj qhov chaw ntawm lub tap kom paub txog qhov voltage regulating ntawm transformer raws li qhov xav tau. Tab sis tsuas yog tom qab lub transformer raug txiav tawm ntawm lub network hluav taws xob, thaum lub transformer nyob rau hauv lub xeev tawm-curcuit, peb tuaj yeem ua haujlwm hom tap-changer no.
2. Cov kev tsis sib xws
| Cov Lus Qhia Tshwj Xeeb | WDP63 | WDP125 | |
| Tus lej theem | Ib theem xwb | ||
| Hom kev sib txuas | Nruab Nrab | ||
| Ntsuas los ntawm tam sim no (A) | 63 | 125 | |
| Kev luv luv muaj peev xwm | Kev ruaj khov ntawm cua sov tam sim no (KA / 2S) | 1.6 | 2.5 |
| Kev ruaj khov ntawm dynamic tam sim no (KA) | 4 | 6.25 | |
| Zaus ntsuas (HZ) | 50 ~ 60 | ||
| Kev rwb thaiv tsev theem (KV) | Qhov ntsuas hluav taws xob (KV) | 10KV | 35KV |
| Lub zog-zaus tiv taus Hluav taws xob (50HZ / 1min) | 42KV | 95KV | |
| Impulse (1.2 / 50μS) | 75KV | 250KV | |
| Kev Ua Haujlwm Sealing (KPa / 24 teev) | 60 | ||
| Lub neej tshuab (Txhiab lub sijhawm) | 2 | ||
2. Siv Cov Xwm Txheej
| Nruab nrab rwb thaiv tsev | Kub ℃ | |
| qhov kub qis tshaj plaws | kub tshaj plaws | |
| Huab cua | -25 | 40 |
| Roj | -25 | 100 |
3. Cov yam ntxwv
Kev siv tshuab laus thiab kev ntseeg siab siab:
Muaj peev xwm nqa tam sim no thiab lub neej ua haujlwm ntev:
Kev saib xyuas yooj yim heev:
Haum rau high voltage thiab loj tam sim no:
4.Cov ntawv thov
Rotary Off-Ioad Tap changers yog cov khoom siv txheem rau cov hluav taws xob siab, hluav taws xob ntxiv thiab cov hluav taws xob loj thiab siv dav hauv:
Kev sib kis thiab kev hloov pauv ntawm lub zog fais fab:cov transformers tseem ceeb hauv 500kV, 220kV, 110kV thiab lwm yam substations.
Cov teb ua lag luam: arc furnace transformers, rectifier transformers thiab lwm yam sijhawm uas xav tau kev tswj hwm voltage ntau zaus thiab meej.
Cov chaw tsim hluav taws xob:cov generator step-up transformers.
Daim Ntawv Ceeb Toom
1) Qhov chaw teeb tsa yuav tsum tsis txhob muaj cov pa roj tawg thiab corrosive.
2) Ua ntej sib sau ua ke lub tapping switch, yuav tsum xyuas seb lub tapping switch puas ua raws li hom kev qhia ntawm lub transformer kom tsis txhob ua rau muaj kev poob uas yuav tsum tsis txhob tshwm sim.
3) Cov xov hlau ua ntej ntawm lub davhlau ya nyob twg ntawm lub qhov hloov pauv yuav tsum tsis txhob ua rau lub qhov hloov pauv hloov pauv vim muaj kev ntxhov siab thiab cov xov hlau ua ntej thiab qhov txav mus los yuav tsum muaj qhov chaw txav mus los txaus (feem ntau 10 hli) kom tsis txhob muaj kev cuam tshuam rau kev txav mus los.
4) Qhov kub siab tshaj plaws ntawm qhov hloov no yog 110 ℃, yog tias tom qab ziab, Yog tias qhov kev tiv tauj loj dhau, yuav tsum khiav rov qab ob peb zaug.
5) Thaum lub qhov hloov pauv nyob rau hauv qhov chaw iav siab tshaj plaws, txwv tsis pub rub lub tes tuav mus rau qhov kev taw qhia txwv.
6) Ua ntej sib dhos thiab hloov pauv, yuav tsum ua 3 ~ 5 zaug ntawm kev hloov pauv ntawm qhov chaw tapping ntawm qhov hloov pauv tapping, thaum qhov tapping tau ua tiav qhov kev hloov pauv tswj hwm, qhov kov hloov pauv yuav tsum muab tso rau hauv qhov flange locating slot.